Most chiller plants are sized for the design day and run there forever. Ours runs for today's weather.
Adaptive · not fixed
CHW supply, CDW supply, tower-fan speed, pump-VFD setpoints — all reset against today's wet-bulb and today's load. Finds the daily plant minimum kW/TR; doesn't sit at the design-day number forever.
Whole-plant supervisory
Chillers, pumps, tower, AHUs, VAVs and FCUs sequenced as one system. Lead/lag/standby on runtime balance, trim-and-respond on the AHU header, demand-control on every zone.
Free-cooling — armed
Waterside hand-off when CDW return < CHW return + Δ. Airside enthalpy on every AHU. Most buildings have 200–400 free-cooling hours a year hiding from their BMS. Ours catches them.
End-to-end. Not just a device.
A solution is hardware in the field plus the infrastructure that makes the data useful — secure ingestion, a dashboard your team actually opens, and APIs to whatever runs your business.
// Deployments can run on Sensoverse Cloud, on your VPC, fully on-prem, or hybrid. Data residency: India (Mumbai) and UAE (Dubai) regions available.
Eight control loops. One stack.
Pick a row — see how the loop closes.
A BMS reports the plant. Ours runs it.
Most BMSs sit on top of the chillers' factory controllers, scrape values into a database and trend them on a screen. They schedule, they alarm, and that's about it. The cost reduction comes from closing the loops the factory controller can't see — across chillers, towers, pumps and air-side at the same time.
What your team sees.
Live KPIs, drill-downs, scheduled reports, and role-based access — out of the box. Custom widgets and white-label themes available.
- COP drop > 10%
- Approach > 2 °C
- VFD fault
- Sensor fail
Built for plant & campus IT.
Industrial sites have non-negotiables — segmentation, audit trails, and the ability to run when the WAN drops. We design for that on day one.
How customers use it.
Real applications, real outcomes. Every site is engineered — these are reference deployments to anchor a conversation.
The full HVAC-control stack.
Plant controller, VFD interfaces, AHU / FCU / VAV controllers, sensor packs, tower + pump controllers, and the Sensoverse Energy platform. Sized to your plant after a one-call scoping.
Engineering data.
// Indicative — full datasheet on request.
Where it's running, right now.
Five-star hotel · Mumbai
Adaptive CHW + CDW reset cut plant kW/TR from 0.81 → 0.66 over six months. 18% cooling kWh reduction; payback in 11 months on a 5-yr-old plant.
Commercial tower · Dubai
AHU sequencing + free-cooling logic unlocked 320 free-cooling hours/yr. Peak demand cut 8%; tenant CHW sub-billing automated for the first time.
University campus · UAE
Plant COP improved 4.9 → 5.8 over six months by adaptive condenser-water reset alone. Thermal storage sequencing aligned with peak-tariff windows.
A 30-day plant audit. For a fixed fee.
Drop our gateway on the plant LAN for 30 days. We come back with a measured kW/TR baseline, a sized BOM, an opportunity list and a fixed-price quote — credited against the project if you proceed.